1.
J Neurosci Nurs ; 54(1): 30-34, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-35007261

RESUMO

ABSTRACT: BACKGROUND: The Bispectral (BIS) monitor is a validated, noninvasive monitor placed over the forehead to titrate sedation in patients under general anesthesia in the operating room. In the neurocritical care unit, there is limited room on the forehead because of incisions, injuries, and other monitoring devices. This is a pilot study to determine whether a BIS nasal montage correlates to the standard frontal-temporal data in this patient population. METHODS: This prospective nonandomized pilot study enrolled 10 critically ill, intubated, and sedated adult patients admitted to the neurocritical care unit. Each patient had a BIS monitor placed over the standard frontal-temporal location and over the alternative nasal dorsum with simultaneous data collected for 24 hours. RESULTS: In the frontal-temporal location, the mean (SD) BIS score was 50.9 (15.0), average minimum BIS score was 47.0 (15.0), and average maximum BIS score was 58.4 (16.7). In the nasal dorsum location, the mean BIS score was 54.8 (21.6), average minimum BIS score was 52.8 (20.9), and average maximum BIS score was 58.0 (22.2). Baseline nonparametric tests showed nonsignificant P values for all variables except for Signal Quality Index. Generalized linear model analysis demonstrated significant differences between the 2 monitor locations (P < .0001). CONCLUSION: The results of this pilot study do not support using a BIS nasal montage as an alternative for patients in the neurocritical care unit.


Assuntos
Monitores de Consciência , Eletroencefalografia , Adulto , Sedação Consciente , Humanos , Hipnóticos e Sedativos , Unidades de Terapia Intensiva , Projetos Piloto , Estudos Prospectivos
2.
J Intensive Care Med ; 35(7): 650-655, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29742951

RESUMO

OBJECTIVE: Evaluation of common carotid artery (CCA) blood flow can provide valuable information regarding the hemodynamic status of a patient. Utilizing ultrasound, we aimed to evaluate the correlation between cardiac output and different hemodynamic parameters in the CCA, namely systolic carotid flow (SCF), corrected flow time (CFT), and total carotid flow (TCF). METHODS: We studied a pilot sample of 20 healthy volunteers. Hemodynamic parameters were collected in the right CCA and the heart at rest (baseline), 1-leg compression, 2-leg compression, and passive leg raise. Nonparametric Spearman correlation was calculated using STATA 13 software. RESULTS: This study demonstrated the feasibility and safety of the leg compression testing as a hemodynamic maneuver to simulate volume depletion status. We demonstrated a direct correlation between cardiac output and SCF of 0.67 with a P value < 0.001. Interestingly, TCF calculated based on volume-time integral (VTI) in the carotid artery showed positive correlation of only 0.41, with P < 0.06, and it did not reach statistical significance. We also found a positive correlation between CFT and cardiac output at baseline 0.57, with P < 0.001. CONCLUSION: Variations in cardiac preload and the subsequent alterations in cardiac output were directly translatable into variations in the carotid blood flow. This supports the potential for using carotid flow as a surrogate for cardiac output. The most promising parameters were SCF, CFT, and carotid systolic VTI. Further work is needed to validate these correlations and utilize these acquired carotid parameters to guide fluid management and predict fluid responsiveness.


Assuntos
Débito Cardíaco/fisiologia , Artéria Carótida Primitiva/fisiologia , Hemodinâmica/fisiologia , Perna (Membro)/irrigação sanguínea , Fluxo Sanguíneo Regional/fisiologia , Ultrassonografia/métodos , Adulto , Biomarcadores/análise , Estudos de Viabilidade , Feminino , Voluntários Saudáveis , Humanos , Masculino , Projetos Piloto , Pressão , Estatísticas não Paramétricas
3.
Artigo em Inglês | MEDLINE | ID: mdl-26486114

RESUMO

This case reveals a left pulmonary arteriovenous malformation (PAVM) as a cause of recurrent cerebral and cerebellar emboli. Extensive workup excluded other etiologies of emboli formation, and the patient was transferred to a tertiary care center for percutaneous embolotherapy. In the absence of a clear etiology, PAVM should be considered as a potential cause of recurrent cerebral emboli, especially in the absence of carotid disease, intracardiac thrombus, atrial septal defect, and patent foramen ovale. Diagnostic work-up for the PAVM can be cost effective and expedited by utilization of agitated saline contrast echocardiography, as noted in our case.